Roof windows · Folkestone
Velux roof windows and skylights installation in Folkestone
New openings, like-for-like swaps, flashing kits, reglazing and leak repairs for roof windows and skylights in Folkestone and across south-east Kent, each one judged on the roof first.
10-year workmanship guarantee, in writing

Velux and skylight questions, answered
All guidesThe fair ledger
Six roof window decisions, from a new opening to a leak
Velux installation in Folkestone covers more than fitting a new window. Each entry below sets out one job on the roof, what we check first, and which way the verdict falls.
Entry 01New opening
Cutting a new roof window into a sound slope
A new roof window means cutting through tiles, battens, underlay and at least one rafter. Before any of that happens, we check that the slope can take it.

How we plan a new opening before we cut
We start in the loft or the room below, not on the roof. We measure the rafter spacing, because the width of the window decides whether a rafter has to be cut and the timbers either side trimmed to carry the load around the gap. We look for cables, pipes and extractor runs where the opening would go, and we check the underlay and battens for damp: a window set into a wet slope only moves the problem somewhere new.
Outside, we note the covering, whether interlocking tiles, plain tiles or slate. That decides the flashing kit and how many courses come off around the frame. The tiles we refix beside the window go back to a fixing specification calculated for that roof under BS 5534, and a house near the coast is graded with higher exposure in that sum.
Then the inside: where the lining panels will sit, how deep the reveal is, and whether the window can be fitted from inside the room or needs scaffold. Our page on what a Velux window costs to fit explains how each of those choices moves the cost.
- Tile or slate cut back around the frame
- Battens cut and nailed off
- Underlay collar dressed up to the frame
- Rafters trimmed either side of the opening
The window sits between rafters, with the underlay folded up to meet its frame.
Myth: Every new roof window needs planning permission.
Fact: On a house it is normally permitted development under Class C, subject to its conditions; flats, listed homes and Article 4 areas are different.
1.4 W/m²K
the limit Approved Document L 2021 sets for a new roof window, or WER Band B
Table 4.2, used until 24 March 2027
What sets the price
- Window size and how many
- Tile, slate or flat roof
- Rafters cut and trimmed
- Plaster and lining inside
One written total price
Planning and building control for the opening
On a house, a new roof window is normally an alteration to the roof under Class C permitted development, with conditions on how far it may stand proud of the slope and on windows in a side slope. Our guide to planning permission for Velux windows sets those conditions out in full. A flat sits outside permitted development altogether, so a roof window on a flat needs planning permission.
Building control is a separate question. Dover District Council's list of work needing approval includes installing roof lights, so for homes in Dover, Deal and Sandwich we confirm the route with that council before booking the job. Elsewhere we ask the council's building control team first. A new roof window also counts in the Planning Portal's building envelope test, which names roof windows and roof-lights among the parts of a home's envelope, and the window itself has to meet the energy limit shown in the figure beside this entry.
- Slate lifted beside the frame
- Batten the slate hangs on
- Clip that holds it back in place
Slates beside the frame come off for the swap and go back on clips.
Entry 02Replacement
Replacing an old Velux in the opening it already has
When the frame has rotted or the sash will no longer close, a new window in the same opening beats a third patch on the old one.
How long does a like-for-like roof window swap take?
Less time than a new opening, because no rafter is cut and nothing inside needs re-plastering. The time depends on reaching the window safely and on the covering around it. We put the expected days in writing, so you can plan around the room being out of use.

What we found
Misting between panes, frame still sound
New glazing unit only
Bottom rail soft and stained
New window, same opening
Sash dropped, seals flattened
Check the hinges first
Signs an old roof window has had its day
A roof window wears out from the inside as well as the outside. The signs we look for are a timber frame gone soft along the bottom rail, where condensation runs down and sits; a sash that has dropped and no longer seals against the frame; a hinge or handle that has seized; and misting between the two panes that will not wipe away. One of those on its own can be a repair. Several together, on a window that also lets in draughts, point to replacement.
A like-for-like swap keeps the opening. Where a window is made in the same size, the old frame comes out, the new one goes into the same space, and the tiles or slates around it are lifted and refixed over a new flashing kit. On a slate roof, the slates beside the frame are refixed with clips, as the drawing shows, since the course above leaves no room to nail them a second time. The rafters and the plaster inside stay as they are, which keeps a swap a smaller job than a new opening. Our page on replacing a Velux window like for like walks through it.
Send us a photo of your roof window
Get a fair verdictUpgrades we fit at the same visit
A replacement is the easy moment to change how the window works. A top-hung window opens outward from the top and leaves a clear view; a centre-pivot window turns on its middle so you can clean the outer pane from inside the room. Electric and solar-powered windows open from a switch or a remote, which helps where the window sits out of reach above a stair; a mains window needs a supply at the frame, so we agree the cable route with you before the lining goes back. Blinds can go in at the same visit: blackout blinds for a bedroom, or an awning blind on the outside to shade the glass in summer.
Velux is one make among several. If you are weighing it against the alternatives, our comparison of Velux, Keylite and Fakro sets the three side by side. Whichever you choose, the new window must meet the current energy limit for roof windows given in the first entry.
Entry 03Flashing
A leak round the frame, and the flashing kit behind it
A drip on the sill or a stain on the lining under a roof window can come from the flashing, the glazing or the room itself. We find which before anything is replaced.
How a flashing kit keeps the rain out
A roof window is sealed to the roof by its flashing kit, not by sealant. The kit is a set of shaped metal pieces: an apron that lies over the tiles below the window, side pieces that run under the tiles at each side, and a top piece that tucks under the course above. Each kit is made for a covering profile, so the kit for deep interlocking tiles is a different part from the one for flat slates. Beneath it, an underlay collar catches anything that gets past and leads it out over the tiles below.
Leaks start where that order breaks. A tile above the frame has slipped and lifted the top piece. Moss and leaves have dammed the channel at the head of the window. An earlier fitter used the wrong kit for the tile, or ran a bead of mastic instead of tucking the side pieces under the courses. On older windows set in lead, the apron may have split or lifted away from the tiles.
Myth: A bead of sealant round the frame will stop the leak.
Fact: Mastic hides the gap for a season at best; the flashing kit, lapped under the tiles, is what sheds the rain.
Code 4
the lightest lead sheet Royston Lead lists for flashings
Royston keeps Code 3 for soakers only
Can a leaking roof window be mended without replacing it?
Yes, where the frame and glazing are sound. Re-seating the flashing kit and refixing the tiles around it cures a leak at the flashing, and a failed glazing unit can be changed in the old frame. A rotten frame or a broken sash is the point at which a new window makes sense.
Repair the flashing, or replace the window
If the frame and glazing are sound, the fix is the flashing: lift the tiles round the window, refit or renew the kit to suit the covering, and refix the tiles. Where an old window is set in lead, we dress new lead to suit, with the code chosen for each detail; our lead work page explains how. If the frame itself is rotten, a new kit on an old window wastes the money, and we tell you that before you spend it.
Our page on why a Velux window leaks covers the other causes, including condensation that looks like a leak but starts in the room.
A little maintenance keeps a flashing working. Each autumn, once the leaves are down, look at the top of the frame for moss and debris where you can reach it from inside, and check from the ground that no tile above the window has slipped. After a gale, a look at the lining for a fresh stain catches a lifted flashing piece before the plaster suffers.


What sets the price
- Size of the glazing unit
- Whether the sash comes out
- Reaching the window safely
One written total price
Entry 04Glazing
Misted or cracked panes: reglazing the window you have
If the frame is sound, a misted or cracked pane does not mean a new window. The glazing unit can be changed on its own.
Mist between the panes, or condensation on the room side
Two kinds of wet glass look alike from the bed and mean different things. Misting between the two panes means the seal around the sealed glazing unit has failed and moist air has got into the gap. It will not wipe off from either side, and it will not clear on a dry day. The cure is a new glazing unit in the existing sash, which is what reglazing means.
Condensation on the room-side face comes from the room, not the window. Warm, damp air from a shower, a drying rack or a bedroom overnight meets the cold pane and settles as water. It runs down to the bottom rail, which is how a frame can rot from the inside on a window that has never leaked. Opening the vent, letting air through during the day and running an extractor in a loft bathroom all help. If you are not sure which you have, wipe the inside face with a dry cloth on a cold morning: if the glass clears, the moisture was on the room side.
Mist inside the double glazing
New glazing unit
Water on the room-side pane
Better room ventilation
Crack across the outer pane
Reglaze the sash
Will a new glazing unit match the rest of the window?
It is made for the sash it goes into, so the size and the look match. If several windows share one slope and only one has misted, we tell you whether the others show the same early signs, so you can do them together or leave them for now.
When reglazing is the right call
Reglazing makes sense when the frame is firm, the sash still closes tight and the hinges move freely. We measure the unit and order a replacement made for that sash. On the day, the sash comes out or tilts in, the old unit is lifted from its seating, and the new one is bedded in with fresh glazing seals before we check the sash closes evenly all round. A cracked outer pane is dealt with the same way, and it pays to act before rain gets between the panes and into the timber. If the frame is soft or the sash has dropped, a new pane in a failing window is money spent in the wrong place, and the replacement entry above is the better route. Our page on Velux reglazing covers cracked panes as well as misted ones.
Entry 05Loft rooms
Roof windows in a loft conversion, and escape from fire
A roof window in a converted loft can be the way out in a fire. That sets its opening size, its height above the floor and the kind of window.
Can any roof window serve as a fire escape?
No. It has to give the clear opening Approved Document B asks for, at the right height above the floor, and serve a storey no higher than 4.5 metres above ground. Some windows are made as escape windows for that reason, and we check the figures against the room before ordering.
Escape windows and the 4.5 metre line
Approved Document B, the fire safety guidance for houses, deals with escape from upper storeys. For a habitable room on a storey up to 4.5 metres above ground, one route out is an emergency escape window. Paragraph 2.10 gives its size: an openable area of at least 0.33 square metres, at least 450 mm high and 450 mm wide, with the bottom of that opening no more than 1,100 mm above the floor. A roof window chosen as an escape window has to meet all three, so we check the clear opening of the exact model, not the frame size printed on the box.
Above 4.5 metres the window no longer does that job. Where a loft conversion creates a storey more than 4.5 metres above ground, paragraph 2.5 asks for a protected stairway or else an alternative escape route, and paragraph 2.23 allows a sprinkler-based option for open-plan layouts. Which one your house needs is for your designer and building control to settle; we fit the windows the approved plan specifies.
0.33 m²
minimum openable area for an emergency escape window, Approved Document B para 2.10
At least 450 mm high and wide
An escape window is measured by the gap you can climb through, not by its frame.

The roof around the new windows
A loft conversion also brings the roof itself under the energy rules. A retained roof above the 0.35 threshold in Table 4.3 of Approved Document L is upgraded to the improved 0.16, so long as that can be done and the simple payback is 15 years or less. The windows sit outside that sum, because roof windows are not thermal elements; each one is judged against its own figure of 1.4 W/m²K or WER Band B. Where we are working on the roof as well as the windows, we set the frames to suit the depth of the new insulation, so the lining meets the plasterboard cleanly.
Position matters as much as size in a loft room. A window set high on the slope throws sky and daylight deep into the room; one set lower gives a view out when you sit or stand. Where a roof window is also the escape window, the 1,100 mm limit on the bottom of the opening comes before the view, so we agree positions with you and your designer before any rafter is cut.
Domes, flat glass and the upstand beneath them
Rooflights in Folkestone extensions and garages come as plastic domes, flat glass units set to a slight fall so rain runs off, and opening versions for ventilation or for access to the roof. Each one sits on an upstand, the raised kerb around the opening, so water lying on the roof stays below the glazing. The roof membrane is dressed up the sides of that upstand and sealed under the rooflight's frame.
Old domes can go brittle, crazed and cloudy, and some crack where they were screwed down. A leak here can come from the upstand rather than the dome: a membrane that has pulled away from the kerb, a timber kerb gone soft, or water ponding against one side because the roof has lost its fall. An opening rooflight over a kitchen lets steam out; a fixed one has fewer moving parts. We look at all of that before choosing the replacement.
Entry 06Flat roofs
Rooflights on a flat roof, from the kerb up
On a flat roof the glazing sits on a raised kerb, and the seal between that kerb and the roof covering does the job a flashing kit does on a slope.

Dome crazed, kerb still firm
New rooflight, same kerb
Membrane lifted away from the kerb
Reseal and dress the membrane
Timber kerb soft to the touch
Rebuild the kerb, then refit
What sets the price
- Rooflight size and type
- State of the kerb
- Membrane work around it
- Access to the roof
One written total price
Replacing a rooflight on a flat roof
Where the dome has failed but the kerb is sound, a new rooflight can go onto the same upstand, sized to it. Where the kerb has rotted, it is rebuilt and the membrane renewed around it, which is a good moment to look at the whole flat roof. Where the roof is sound and only the rooflight has failed, we cut the old frame free, dress fresh membrane up the kerb and fix the new unit down onto it, so the kerb, the membrane and the new glazing finish as one sealed detail. Approved Document L judges a rooflight against its own figure, 2.2 W/m²K, not the roof window figure.
If the flat roof itself is being re-covered, the falls count for as much as the glazing. BS 6229:2025 sets a minimum finished fall of 1:80 on membrane flat roofs, which is why the deck gets laid to a steeper design fall to allow for tolerances, and the rooflight kerb is set level on top of it. Our flat roofing page covers the roof around the rooflight.
- Roof deck around the opening
- Membrane laid over the deck
- Upstand the rooflight sits on
- Drip trim at the roof edge
The membrane runs up the upstand and under the rooflight frame.
Which of these six is your roof window doing?
Send a photo of the window from inside and out, or ask us round. We come back with a verdict, its reason and one written total price.
Roof window and skylight questions
Costs, permission, makes and fitting, for homes in Folkestone and across south-east Kent.
How much should I budget for a new Velux window?
MyJobQuote puts the average cost of a standard mid-range Velux window at £1,100, and says a straightforward swap costs around £100 less, as the opening is already in place. Checkatrade lists rooflight replacement, such as a Velux, from £1,000 in its repair-rate table, which excludes VAT. Both are general guides. On a real job the figure moves with the window size, whether a rafter is cut, the covering, scaffold and the plastering inside. After the survey you get one written total price; any quote you compare it with should say whether VAT and scaffold are included.
Will a roofer fit a Velux window, or do I need a window company?
Yes, and a roofer is the right trade for it, because fitting a roof window is roof work: cutting the opening through the covering, trimming rafters, dressing the underlay, fitting the flashing kit and refixing the tiles or slates so the slope stays watertight. We fit Velux roof windows and other makes, from one window over a landing to a run along a loft conversion. Inside, the lining panels go in and the plaster around the reveal is made good. New floors, stairs or walls in a conversion sit with the builder.
Is planning permission needed for a roof window in a loft?
On a house, a roof window is normally permitted development under Class C, the class for alterations to a roof, provided it meets the conditions our planning guide lists. A flat has no permitted development rights, so it needs planning permission. A listed home keeps its rights, but listed building consent is needed where the work would affect its special character. In a conservation area Class C still applies, though an Article 4 direction can withdraw specified rights, so we check with the local planning authority first. Folkestone & Hythe District Council's interactive map shows whether your street is in one.
Are there other roof window makes besides Velux?
Yes. Keylite and Fakro both make roof windows for pitched roofs, with their own flashing kits, blinds and opening types. Any of them has to meet the same energy limit: 1.4 W/m²K or WER Band B under Table 4.2 of Approved Document L 2021, which applies until 24 March 2027. What matters on your roof is that the window and its flashing kit are made for each other and for your covering, and that a replacement fits the opening you have. For a second make, ask at the survey and we will quote for it too.
When is an old roof window worth upgrading rather than mending?
When the faults are in the window rather than around it. A rotten bottom rail, a sash that has dropped out of line, seized hinges and draughts round a closed sash all point to a new window. A single misted pane, a broken handle or a leak at a sound frame's flashing are repairs. Simple maintenance helps an older window along: clear leaves and moss above the frame, keep the vent filter clean, and open the vent when the room steams up. From 24 March 2027, Approved Document L 2026 sets the limits for new work.
Who handles building control for a roof window around Folkestone?
It depends on the council. Folkestone, Hythe, Sandgate, Cheriton and Hawkinge fall under Folkestone & Hythe District Council, whose building control team is on 01303 853538. Dover District Council names installing roof lights as work needing approval, which covers Dover and Deal. Ashford Borough Council runs its own building control service, on 01233 330282. Canterbury works through the STG Building Control Partnership, and Rye through the East Sussex Building Control Partnership. You can also use a registered building control approver instead of the council, and we confirm which body is involved before booking.
Can a roof window go into a shallow pitch or a flat roof?
On a pitched roof, each window and its flashing kit have a pitch range in the maker's data sheet, and we check your slope against it before ordering. The kit also has to suit the tile or slate profile around it. On a flat roof the answer is a rooflight on an upstand instead: a flat glass unit, a dome or an opening rooflight, sealed into the membrane. Where an extension's flat roof is near the end of its life, renewing the covering and fitting the rooflight in one visit means the seal between them is made once.
Will you need scaffolding to fit my skylight?
Not every time. Some roof windows can be fitted safely from inside the room, working out through the opening. A high window, a steep slope or one above a conservatory can need scaffold or a tower; the survey settles which, and scaffold is part of the quote, never an add-on. Kent County Council's fee for scaffolding on the highway is £52 per week for 2026 to 2027. For Rye and Camber, East Sussex Highways lists £127 for 28 days in its published fees, though the current fee should be checked. Either way, we arrange the licence with our scaffolder.
Tell us what's wrong with the roof.
You'll get one written total price.